Logo
boRn Pte Ltd

We aim to provide services that are Rational, Responsible, and Reasonable to upkeep our Reputation with your Recognition

 

We are appointed distributor/dealer for many well established and reputable leading manufacturers in the fire industry so as to bring you a wide range of price competitive, good quality fire products and solutions. We are confident that you will be able to find a fire product that is suitable for your application from our wide range of well known brand names like VANGUARD, MENVIER, HORING LIH, HONG CHANG, SENTEK and SYNAPS..

Our VANGUARD "V5" Hybrid Fire Alarm Panels are PSB APPROVED TYPE, permissible for any Singapore's new installation and/or old panel's replacement projects. Our Fire Alarm Panels starts with minimum of 4 Zones to maximum of 136 Zones under the PSB Listing. Customized solutions are also available upon request.

Our VANGUARD "V5" Advance Fire Extinguishing Panels has also obtained PSB APPROVAL, It is able to work with most water / gas extinguishing system (FM200, Inert gas, CO2 & water mist etc.) and comes complete with Cross Zone Detection, Voting Logic Circuit (option), two digit countdown display and multiple zones with individual or common firing circuit. These panels are suitable for use in data centers, computer room environment, telecommunication exchange facilities, engine / equipment room etc.

We offer a wide range of Conventional Heat and Smoke Detectors, Manual Call Point, Fire Alarm Bells, Electronic Sounders etc. that will works perfectly well with our range of Fire Alarm Panels as well as any other make of Conventional Fire Alarm Systems. You can be rest assured of the product quality as all our fire devices and accessories are well certified to meet British's LPCB (Loss Prevention Certification Board) or America's UL (Underwriter Laboratories) standards.

   Fire Alarm Panels / Fire Extinguishing Panel
Fire Alarm Panel

VANGUARD
V5 Hybrid Fire Alarm Panel

  • Compatibility: Works with many other make of equipment, panels and devices
  • Flexibility: Wide range of auxiliary panels to meet each requirement, e.g.: Fire Extinguishing, Smoke Control, Pre-action etc.
  • Alarm interlocks: General sounder silencing and system resetting for system with multiple panels.
  • Ease of use: Simple on touch operation - easy to learn and reduces errors.
  • Diagnostic facilities: Informative diagnostic LED indicators for easy identification and rectification of faults.
  • Reliability: System designed with proven solid state detection technology.
  • Compliance: BS EN 54 Parts 2 & 4: 1998 and SS CP-10:2005.
  • Approval: PSB Listed (4 to 136 zones).
Logo-Firescann
Fire Extinguisher Panel

VANGUARD
V5 Advance Fire Extinguishing Panel

  • Flexibility: Wide range of auxiliary functions to meet each requirement e.g. AHU shut down, exhaust fan activation, equipment function remote status monitoring etc..
  • Alarm interlocks: General sounder silencing and system resetting for system with multiple zone panel.
  • Ease of use: Simple on touch operation - easy to learn and reduces errors.
  • Diagnostic facilities: Informative diagnostic LED indicators for easy identification and rectification of faults.
  • Facilities: Two digits timer countdown display, remote/local manual release & abort functions, 1st & 2nd alarm auxiliary output etc.
  • Reliability: System designed with proven solid state detection technology.
  • Compliance: BS EN 54 Parts 2 & 4: 1998 and SS CP-10:2005.
  • Approval: PSB Listed (1 to 136 zones).

Back to top

   Fire Detectors
Logo-Menvier
MFR-830
LPCB

MENVIER Conventional Heat Detector
Model: MFR-830

  • Combined ROR/FT Heat Detector.
  • Low profile design.
  • 360° visibility LED's.
  • Operating Voltage: 24VDC.
  • LPCB Approved Type.
Logo-Menvier
MPD-820
LPCB

MENVIER Conventional Smoke Detector
Model: MPD-820

  • Photoelectric Smoke Detector.
  • Low profile design.
  • 360° visibility LED's.
  • Operating Voltage: 24VDC.
  • LPCB Approved Type.

Logo-Menvier
HD921
LPCB
EN54-5

Installation Manual
Click Here


SENTEK Conventional Heat Detector
Model: HD-912

  • Combined ROR/FT Heat Detector.
  • Advanced detection and discrimination algorithms.
  • Flashing LED indicating of power status.
  • Available in 2 or 4 wires type.
  • Operating Voltage: 24VDC.
  • Standby Current: 45µA.
  • Alarm Current: 50mA @24VDC
  • Thermal Setting: 57°C
  • Operating Temperature: -10°C to +50°C
  • Humidity: 0 to 95% RH, no condensation or icing.
  • UL Listed.

Logo-Menvier
SD-119
LPCB
EN54-5/7

Installation Manual
Click Here

SENTEK Conventional Smoke Detector
Model: SD-119

  • Photoelectric Smoke Detector.
  • Advanced detection and discrimination algorithms.
  • Flashing LED indicating of power status.
  • Available in 2 or 4 wires type.
  • Operating Voltage: 24VDC.
  • Standby Current: 80µA.
  • Alarm Current: 55mA @24VDC.
  • Operating Temperature: -10°C to +50°C.
  • Humidity: 0 to 95% RH, no condensation or icing.
  • UL Listed.
Logo-Menvier
SD218
EN14604

SENTEK Standalone Smoke Detector
Model: SD218

  • Photoelectric sensing technology.
  • Low-sensitivity warning.
  • Low-battery warning.
  • Test button.
  • Loud alarm sound at 85db/3m.
  • Ambient Temperature: 0°C to 50°C.
  • Humidity: 0 to 95% RH, no condensation or icing.
  • Battery operated: 9VDC
  • Standby Current: 8µA.
  • Alarm Current: 15mA.
  • Long lasting Lithium battery model available on MOQ request.

 

 

 

 

 

 

 

 

 

Back to top

 
   Fire Devices & Accessories

Synaps Logo
R6847L_1
R6847L_2
LPCB

Installation Manual
Click Here

SyCALL® Conventional Resettable Manual Call Point
Model: R6847L

  • Resettable type.
  • Very high visibility of alarm condition with LED lights on front and side.
  • Visible in the dark.
  • New efficient and reliable mecahnism.
  • Made of high Resistant material.
  • Design fully comply with EN54-11.
  • LPCB Approved Type.
  • Clear Safety Cover available separately.

Horing Logo
AH-0217
LPCB

Installation Manual
Click Here

HORING LIH Conventional Manual Call Point
Model: AH-0217

  • Flush or Surface Mount..
  • Plastic film on glass - prevents cuts on hand.
  • Test key insert from bottom..
  • Suitable for use in majority conventional fire alarm system..
  • LPCB Approved Type.
  • Clear Safety Cover available separately.

Horing Logo
AH-0218
LPCB

Installation Manual
Click Here

HORING LIH 6" Fire Alarm Bell
Model: AH-0218

  • High efficiency, low current consumption.
  • 93 dB / M & above.
  • Fitted with two series diodes for fault monitoring.
  • Fully suppressed and no interference with other equipment.
  • Dimension: Ø6" (152mm) x 56mm(H)
  • Weight: 850g
  • LPCB Approved Type.


HL-624
Installation Manual
Click Here

HONG CHANG 6" Fire Alarm Bell
Model: HL-624

  • High efficiency, low current consumption.
  • 93 dB / M & above.
  • Fitted with two series diodes for fault monitoring.
  • Fully suppressed and no interference with other equipment.
  • Dimension: Ø6" (152mm) x 56mm(H).
  • Weight: 850g.
  • UL Approved Type.

Horing Logo
AH-9718

HORING LIH 4" Fire Alarm Bell
Model: AH-9718

  • Low current consumption (28mA).
  • 90 dB / M & above.
  • Bell shell is made of steel plate.
  • Dimension: Ø4" (100mm) x 50mm(H).
  • Weight: 450g.


Back Box
Installation Manual
Click Here

HONG CHANG Alarm Bell Back Box
Model: HL-BB

  • Outdoor Back Box for HL-624 Fire Alarm Bell.
  • Rubber Gasket included.
  • Conduit Fitting: NPT 1/2".


AH-03127
LPCB

Installation Manual
Click Here

HORING LIH Electronic Sounder Model: AH-03127-S/BS

  • High sound output with low current consumption.
  • Max. 114 dB.
  • 32 signal tones selectable by Dip switch.
  • Two sets of IN and OUT terminals, easy for installation.
  • Beacon model available (BS).
  • Dimension: Ø92.5mm x 94mm / Ø92.5mm x 110mm
  • Weight: 254g / 278g.
  • LPCB Approved Type.

Horing Logo
AH-01313

HORING LIH Remote LED Indicator
Model: AH-01313

  • Used with 3 or 4 wire type detectors for remote area.
  • Low current consumption.
  • Parallel type wiring.
  • Alarm Current: 12mA (24VDC).
  • Fire proof plastic, White surface / Red LED.
  • Dimension: 70mm(H) x 70mm(W) x 15mm(D).

Smoke Spray Tester

  • Easy to use, simply spray on detector.
  • Safest way of testing Smoke Detector.
  • Disposable after use.
Horing Logo
Testing Kit
User Manual
Click Here

HORING LIH Detector Test Device
Model: AH-03128

  • Applicable for testing of heat & smoke detectors
  • Extension pole included, expanding from 1.44M to 5M length.
  • Pivoted test vessel, for easy to reach detector during testing.
  • Heat detector testing is via gas igniter that generate heat (not naked flame).
  • Smoke detector testing via smoke tester that fits nicely inside the test vessel.

 

 

Back to top

 
Address: 51 Ubi Avenue 1 #05-27 (7C) Paya Ubi Industrial Park Singapore 408933 . Tel: +65-6844 8901 . Fax: +65-6844 6101 . Email:sales@born.com.sg
Copyright © 2009 . boRn Pte Ltd. All Right Reserved